한국생산제조학회 학술지 영문 홈페이지

Journal Archive

Journal of the Korean Society of Manufacturing Technology Engineers - Vol. 28 , No. 5

[ Best Paper of This Month ]
Journal of the Korean Society of Manufacturing Technology Engineers - Vol. 28, No. 5, pp. 267-273
Abbreviation: J. Korean Soc. Manuf. Technol. Eng.
ISSN: 2508-5107 (Online)
Print publication date 15 Oct 2019
Received 18 Sep 2019 Revised 10 Oct 2019 Accepted 15 Oct 2019
DOI: https://doi.org/10.7735/ksmte.2019.28.5.267

투과형 전자현미경의 고니오미터형 시료 구동 스테이지의 설계
최기봉a, * ; 이상철b

Design of a Goniometer-type Specimen Stage for Transmission Electron Microscopy
Kee-Bong Choia, * ; Sang-Chul Leeb
aDept. of Nano manufacturing Technology, Korea Institute of Machinery and Materials, 156, Gajeongbuk-ro, Yuseong-gu, Daejeon 34103, Korea
bElectron Microscopy Research Center, Korea Basic Science Institute, 169-148, Gwahak-ro, Yuseong-gu, Daejeon 34133, Korea
Correspondence to : *Tel.: +82-42-868-7132 Fax: +82-42-868-7721 E-mail address: kbchoi@kimm.re.kr (Kee-Bong Choi).

Funding Information ▼

Abstract

In this study, a goniometer-type specimen stage for transmission electron microscopy is proposed. The specimen stage is mounted on the side of the vacuum chamber of a transmission electron microscope. A specimen is transported from the environment to the vacuum chamber via a holder, where positioning of the specimen is then conducted. The specimen stage comprises three translations and one rotational motion. As two translations are approximated linear motions, which are a part of the tilt motions, the term ‘goniometer’ is used. The actuation systems have been designed with consideration for the workspace and resolution. An air-locking device was also designed to separate the vacuum chamber from the atmosphere. Finally, the specimen stage was manufactured using aluminum and stainless steel to avoid the effect of a magnetic field. Experiments were then conducted to evaluate the performance of the proposed solution.


Keywords: Transmission electron microscopy, Goniometer, Specimen stage, Holder, Air-lock mechanism

Acknowledgments

이 연구는 2019년 과학기술정보통신부의 재원으로 한국기초과학지원연구원 분석화학 연구장비개발 사업의 지원을 받아 수행되었습니다(주관연구사업코드 D35612).


References
1. Goldstein, J. I., Newbury, D. E., Michael, J. R., Ritchie, N. W. M, Scott, J. H., Joy, D. C., 2018, Scanning Electron Microscopy and X-Ray Microanalysis, Springer, New York.
2. Flegler, S. L., Heckman, J. W., Klomparens, J. K. L., 1997, Scanning and Transmission Electron Microscopy, W. H. Freeman and Company, New York.
3. Williams, D. B., Carter, C. B., 2009, Transmission Electron Microscopy, Springer, Boston, MA.
4. Pulokas, J., Green, C., Kissenberth, N., Potter, C. S., Carragher, B., 1999, Improving the Positioning Accuracy of the Goniometer on the Philips CM Series TEM, J. Structural Biology, 128:3 250-256.
5. Vingsbo, O., Yanaka, T., Shirota, K., 1975, A method of using the incident beam tilt as a eucentric goniometer in transmission electron microscopy, Ultramicroscopy, 1:2 121-126.
6. Svensson, K., Jompol, Y., Olin, H., Olsson, E., 2003, Compact design of a transmission electron microscope-scanning tunneling microscope holder with three-dimensional coarse motion, Rev. Scientific Instruments, 74:11 4945-4947.
7. Bobji, M. S., Ramanujan, C. S. , Pethica, J. B., Inkson, B. J., 2006, A miniaturized TEM nanoindenter for studying material deformation in situ, Meas. Sci. Technol., 17:6 1324-1329
8. Delta Tau, 2016, User manual Power PMAC IDE, Delta Tau Data Systems, Inc..